We are licensed distributor for a comprehensive range of industry-standard HVAC tools and equipment brands, catering to both commercial applications and the specialized requirements of sectors such as Oil & Gas, Mining, and Maritime, which demand highly qualified tools and equipment.
Our portfolio includes the following brands:
ASADA CORP. – JAPAN
ASADA Corporation is a Japanese manufacturing company, established in 1941. In HVAC category they are well known for supreme quality HVAC Tools like refrigerant recovery & reclaim machines. Apart from that, their range of tools covers many key functional areas like threading, cutting, inspection, refrigerant recovery etc.
ECOcycle AURORA Ⅱ World’s-first electrostatic separation technology

- Patented electrostatic separation technology. Electrostatic separation method removes moisture and oil. a small device with capability equal to a huge reclaim plant system.
- High purity reclaim (99.9%) of used refrigerant by electrostatic separation technology (Applicable to R410A)
- Impurities in refrigerant are charged by friction with needle valve, and these charged impurities are removed by the electrostatic precipitator. Moisture in the refrigerant which has no impurities is removed by filter-dryer and reclaim used refrigerant as almost pure.
- Applicable to mixed refrigerants. Possible to minimize a composition change in mixed refrigerants such as R410A.
| Item | ECOCYCLE AURORAⅡ |
| Code No. | AR023A |
| Applicable refrigerant (recovery & reclaim) | R12, R22, R32, R500, R502, R134a, R404A, R410A, R507A, R509A, R1234yf |
| Applicable refrigerant (recovery) | R22, R32, R134a, R404A, R407C, R410A, R1234yf etc. |
| Recovery method | Liquid recovery (Vapor recovery is also possible) |
| Reclaim method | Electrostatic separation method |
| Voltage | 220-240V |
| Compressor | 750W, oil-less |
| Oil separator | Heat exchange style, Capacity 2L |
| Weight | 60kg |
| Operating temperature | 5~35°C |
| Applicable cylinder | Float sensor: RECOVERY CYLINDER WITH FLOAT SENSOR (6L. 12L, 24L, 40L, 120L) Weighing: ROCEVERY CYLINDER WITHOUT FLOAT SENSOR(24L, 120L) |
| Standard accessories | 1/4″CHARING HOSE183cm WITH BALL VALVE(red, blue) x each 1pce AR FILTER CORE, FILTER |
ECOsaver V240SP

- High durability 1HP compressor. High speed portable recovery machine has a 1HP twin compressor.
- Stable cooling capacity. Large air flow geared fan with clutch function cools down the condenser and compressor stably.
- Stable start and running. Two capacitors for starting and running ensures stable operation even at low voltage.
- Easy operation. Anyone can operate easily with single valve
- Self-cleaning function. Residual liquid refrigerant in the machine can be recovered to the cylinder to prevent the refrigerants from mixing.
| Item | ECOsaver V240SP |
| Code No. | ES641 |
| Applicable refrigerant (recovery & reclaim) | R12, R22, R32, R500, R502, R134a, R404A, R410A, R507A, R509A, R1234yf |
| Applicable refrigerant (recovery) | R22, R32, R134a, R404A, R407C, R410A, R1234yf etc. |
| Recovery method | Compressed vapor recovery method/Push-pull method |
| Reclaim method | Electrostatic separation method |
| Voltage | 220~240V(50/60Hz) |
| Compressor | 750W Oil-less twin cylinder |
| Weight | 16.3kg |
| Operating temperature | 0~40°C |
| Ultimate vacuum | Max. -0.09MPa |
| Applicable cylinder | Float sensor: RECOVERY CYLINDER WITH FLOAT SENSOR (24L, 40L, 120L) Weighing: RECOVERY CYLINDER WITHOUT FLOAT SENSOR (24L, 120L) |
| Standard accessories | 1/4″CHARGING HOSE 152cm, 1/4″ CHARING HOSE WITH BALL VALVE 152cm, HOSE ADAPTER FOR R410A 5/16″ FEMALE×1/4″MALE, FILTER, SHOULDER BELT, POWER CORD |
ECOsaver Tetra

- Quadruple compressor. New designed horizontally opposed quadruple compressor increases liquid / vapor recovery speed significantly. Horizontally opposed pistons are free from poor compression by wear and it maintains maximum performance.
- Compact & light weight. Can be carried by one person as it weights only 22kg and compact.
- High durability & long life. High speed turbine fan cools down compressor head and condenser, and realizes high efficiency and durability. Refrigerant never enter to the crank case and it prevents damage on bearings etc. Possible to recovery refrigerant which contains no oil too.
- Outstanding recovery rate. Easy to recover even from large systems.
- Self-cleaning function. Residual liquid refrigerant in the Machine can be recovered to the cylinder to prevent the refrigerants from mixing.
| Item | ECOsaver Tetra |
| Code No. | ES802 |
| Applicable refrigerant (recovery & reclaim) | R12, R22, R500, R502, R115, R125, R218, R134a, R401A, R401B, R402A, R402B, R404A, R407A, R407B, R407C, R407D, R407E, R407H, R32, R410A, R410B, R422A, R422D, R448A, R449A, R452A, R463A※, R463AJ, R507A, R509A, R1234yf, R1234ze |
| Recovery method | Compressed vapor recovery method/Push-pull method |
| Voltage | 220~240V(50/60Hz) |
| Compressor | 750W Oil-less twin cylinder |
| Weight | 16.3kg |
| Operating temperature | 0~40°C |
| Ultimate vacuum | Max. -0.09MPa(-675mmHg) |
| Applicable cylinder | Float sensor: RECOVERY CYLINDER WITH FLOAT SENSOR (24L, 40L, 120L) Weighing: RECOVERY CYLINDER WITHOUT FLOAT SENSOR (24L, 120L) |
| Standard accessories | 3/8″ CHARING HOSE 153cm 2pcs、3/8″ BALL VALVE FEMALE×MALE HOSE ADAPTER FOR R410A 5/16″FEMALE×3/8″MALE, HOSE ADAPTER 1/4″FEMALE×3/8″MALE, FILTER |
BACHARACH USA
Bacharach offers innovative solutions for precision instrumentation that makes HVAC-R safer, cleaner, and more energy-efficient. Through over 100 years of innovation, Bacharach is proud to provide customers with clean-tech solutions for gas and refrigerant leak detection, combustion and emissions analysis instrumentation, and energy management for commercial and industrial applications. in HVAC industry Bacharach is famous for their portable gas detection and monitoring instrumentation.
Single- and Multi-zone Aspirated Leak Detectors

- 1 ppm Minimum Detectable Level. Detects leaks that other instruments can’t
- Early detection of refrigerant leaks. Mitigate refrigerant loss, protect produce, enhance energy efficiency
- Monitors up to 16 remote areas, expandable to 48 monitoring points. Ideal solution for grocery store refrigerant monitoring
- Over 50 different refrigerants accurately detected. Monitor multiple refrigerant circuits with a single detection system
- Infrared sensor technology. Accurate, precise measurement unaffected by other gases, temperature or humidity
- High performance sampling pump. Industry-leading cycle times for monitoring all zones with greater frequency
- Minimal maintenance and no calibration required. Low cost of ownership
- Halogen, CO2 and NH3 versions available. Suitable for a variety of refrigerant monitoring applications
| Measurement | Unit | Description |
| GAS LIBRARY | HGM-MZ | FA188, FC72, H1211, H1234ZE, H1301, H2402, HFP, N1230, N4710, N7100, N7200, N7300, N7600, R-11, R-113, R-114, R-12, R-124, R-125, R-21, R-227, R-23, R-236fa, R-245fa, R-401A, R-402A, R-402B, R-404A, R-407A, R-407F, R-408A, R-409A, R-422A, R-422D, R-424A, R-426A, R-427A, R-438A, R-448A, R-449A, R-452A, R-452B, R-500, R-502, R-503, R-507, R-508B, R-513A, R-514A, R-1233zd, H1233ZDE, N4710, R448A, R449A, R513A, R452A, R452B, R514A, H1336E, H1336Z, N5110, R454A, R454C, R455A, HFO1224YDz, FC-3284 |
| CO2-MZ | Carbon Dioxide (CO2), R744 | |
| MEASURING RANGE | HGM-MZ | All gases 0 to 10,000 ppm |
| CO2-MZ | Carbon Dioxide 0 to 8,000 ppm | |
| Accuracy | HGM-MZ | 1 ppm Minimum Detectable Level (MDL) (most gases) ±1 ppm ±10% of reading from 0-1,000 ppm (most gases) ±1 ppm ±2% of reading with field calibration (most gases) ±10 ppm ±15% of reading from 0-1,000 ppm (R-11, R-21, R-32, R-113) |
| CO2-MZ | ±5 ppm ±5% of reading from 0-1,000 ppm, ±10% of reading from 1,000-4,000 ppm, ±15% of reading from 4,000-8,000 ppm | |
| TEMPERATURE DRIFT | HGM-MZ | ±0.8% (R-134a) of reading per degree C between purge cycles |
| CO2-MZ | Less than 1 ppm per degree C between purge cycles |
MGS-550 Dual Gas Detector

- IP66-rated enclosure protects from dust and water ingress
- Two-sensor capability allows for unparalleled flexibility and enables detection of multiple target gases in a variety of ranges or locations (local and remote sensors available)
- 5-digit LED display shows real-time concentration readings and makes configuration and self-diagnostics intuitive
- Configurable analog output (4-20mA, 0-5V, 0-10V, 1-5V or 2-10V) and Modbus communications for integration with Bacharach’s MGS-408 controller or third-party BMS / BAS control systems
- Three user-configurable relays (fault, low and high alarm) may be used to activate external beacons / sounders, ventilation or other countermeasures
- Integrated audible / visual alarms for refrigeration safety compliance – no additional hardware
| A2L | Yes |
| Alarm | Integrated Audible / Visual Alarm |
| Ambient Temperature | -40 to 122°F (-40 to +50°C) |
| Approvals / Standards | EMC Directives, CE Mark, UL / CSA / IEC 61010-1 |
| Digital Communications | Carbon Monoxide (CO), Hydrocarbons, LPG, Nitrogen Dioxide (NO2), R-1234yf, R-1234ze, R-134a, R-22, R-290 (Propane), R-32, R-404A, R-407A, R-407C, R-407F, R-410A, R-422A, R-422D, R-427A, R-448A, R-449A, R-452A, R-50 (Methane), R-507A, R-513A, R-600 (Butane), R-717 (Ammonia), Oxygen (O2), R-744 (CO2) |
| Product Dimensions (L×W×H) | 8.3” × 8.9” × 3.4” (210 mm × 225 mwm × 85 mm) |
| User Interface | 5-digit, 7-segment red/green LED; configuration push buttons and magnetic switches |
| Wiring | 2 A @ 30 VDC, 0.5 A @ 125 VDC, 0.25 A @ 250 VAC |
| Accuracy | SC – < -10%/+15% of Full-Scale; IR, Cat, EC – < ±5% of Full-Scale |
| Altitude | 0 to 6,560 ft (2,000 m) |
| Analog Communication | 4 to 20 mA, 0 to 5V, 0 to 10V, 1 to 5V, 2 to 10V |
| Enclosure Rating | IP66 |
| Humidity | 5 to 90 %RH, non condensing |
| Operating Voltage | 24 VDC or 24 VAC |
| Supports/Enables Compliance with Industry Codes & Regulations | ASHRAE 15, CSA B52.2, EN 378*, F-Gas Regulation |
| Warranty | 1 Year |
VRF Refrigerant Gas Detection

- Centralized monitoring for multi-occupant applications utilizing the MVR-300™ VRF Refrigerant Gas Detector
- At-a-glance visualization of whole system alarm, fault, or connectivity status
- Continuously monitors up to 100 connected devices for alarm and fault conditions, ensuring and warning in case of any disconnect
- Rolling event log of 100 most recent events (alarms, faults, connectivity, etc.) saved to SD card
- 1 Alarm Relay; 1 Fault Relay; automatic system action to be taken for fault or alarm condition via built-in relays
- Self diagnostics and simple field calibration for easy maintenance
- Commissioning via dynamic device pairing and remote Modbus auto-assign save
| Alarm | Integrated Audible / Visual Alarm |
| Ambient Temperature | 32 to 122°F (0 to 50°C) |
| Buzzer Volume | 80 dB @ 10 cm |
| Display Size | 5 inch 800 × 480 pixels |
| Humidity | Humidity: 5 to 90% RH, non-condensing |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Output | 2 x Relays Modbus |
| Product Dimensions (L×W×H) | 13.56” × 11.43” × 5.46” (344 × 291 × 139 mm) |
| User Interface | 4.5″ Color Touch Display |
| Wiring | 2A @ 30 VDC/250VAC |
| Altitude | 0 to 6,560 ft (2,000 m) |
| Approvals / Standards | CE, UL/CSA/IEC/EN 61010-1 |
| Digital Communications | Modbus RTU via RS 485 |
| Max Number of Sensor Inputs | 100 |
| Operating Voltage | 24 VDC or 24 VAC |
| Product Weight | 7.8 lb (3.54 kg) |
| Warranty | 1 Year |
TASCO JAPAN
Tasco Japan is a prominent name in HVAC tools especially in the category of mechanical tools such as vacuum pump, leak detector and manifold. Since it was established in February 1975, TASCO has expanded its business focusing on air conditioning tools development, manufacturing and import. Effective from April 1, 2015, Tasco Japan Co. Ltd. changes its name to ICHINEN TASCO CO., LTD.
Vacuum Pump (TA150SV-EXP)

- Smallest in class: 215 × 120 × 160 mm. Lightest in class: 2.95kg
- Anti Oil Backflow. Prevents cross contamination of vacuum pump oil and compressor oil by the failure of power supply.
- Large Sight Glass for monitoring vacuum pump oil
- Gas Ballast Valve helps the attainment of deep ultimate vacuum. It also prevents the deterioration of vacuum pump oil.
| Part No. | TA150SV-EXP |
| Free Air Displacement | 1.4CFM (40L/min.) |
| Rotor | Single Stage |
| Ultimate Vacuum | 95 microns |
| Voltage | 220~240V |
| Motor / RPM | 60W 2880 r.p.m. |
| Vacuum Pump Oil Capacity | 90 ml |
| Intake Fitting | 5/16″ (1/2-20UNF) |
| Dimensions / Weight | 120W × 215D × 160H mm / 2.95kg |
| Accessories | 1/4″ Male × 5/16″ Female adapter (TA159P-4) |
| Options | Vacuum gauge kit (TA142MK-EXP, TA142MD), Carrying case (TA150PS, TA150CS-21) |
Leak Detector

- Infrared Detection (NDIR). Dispersive infrared technology quickly and accurately detects the refrigerant leak, and does not react to nuisances such as oil and moisture.
- Long Sensor Life. Provides a long-term stable performance.
- LED Bar Display. The 9 LED bar display from green to red indicates the degree of refrigerant concentration in air.
- Turbo Mode. Quick and easy for identifying the smallest leaks.
- Long Battery Life. 5 hours continuous use after a charge.
| Part No. | TA430D |
| Refrigerants | R410A, R32, R407C, R404A, R134a, R1234yf, R22, R12, etc. |
| Sensitivity | [TURBO]3g/year, [HI] 10g/year, [MID]50g/year, [LO] 100g/year |
| Leak Indication | Audible and Visual LED bar indicator |
| Warm-up Time | 45 seconds |
| Auto-Off | 10 minutes after no activity |
| Operating Environment | 0.40°C, 0-80%RH (non-condensing) |
| Probe | 460mm long, 14mm diameter |
| Battery Type | Rechargeable Li-ion Battery |
| Dimensions and Weight | 198(L)X70(W) ×42.5(H)mm / 365g |
| Accessories | USB Charger (100-240V 50/60Hz), USB Cable, Carrying Casel |
Manifolds

- Class 1.6 accuracy gauges with shock resistance, vibration resistance, pulsation resistance
- Calibration Access Port Capable to adjust to 0 even with the gauge lens on
- Assembled in-house under thorough process control
- Final check before shipping – Japanese commitment
Choose and buy a wide variety of tools as a set.