HVAC Tools & Equipments Products

We are licensed distributor for a comprehensive range of industry-standard HVAC tools and equipment brands, catering to both commercial applications and the specialized requirements of sectors such as Oil & Gas, Mining, and Maritime, which demand highly qualified tools and equipment. 

Our portfolio includes the following brands:

ASADA Corporation is a Japanese manufacturing company, established in 1941. In HVAC category they are well known for supreme quality HVAC Tools like refrigerant recovery & reclaim machines. Apart from that, their range of tools covers many key functional areas like threading, cutting, inspection, refrigerant recovery etc.

ECOcycle AURORA Ⅱ World’s-first electrostatic separation technology

  • Patented electrostatic separation technology. Electrostatic separation method removes moisture and oil. a small device with capability equal to a huge reclaim plant system.
  • High purity reclaim (99.9%) of used refrigerant by electrostatic separation technology (Applicable to R410A)
  • Impurities in refrigerant are charged by friction with needle valve, and these charged impurities are removed by the electrostatic precipitator. Moisture in the refrigerant which has no impurities is removed by filter-dryer and reclaim used refrigerant as almost pure.
  • Applicable to mixed refrigerants. Possible to minimize a composition change in mixed refrigerants such as R410A.
ItemECOCYCLE AURORAⅡ
Code No.AR023A
Applicable refrigerant (recovery & reclaim)R12, R22, R32, R500, R502, R134a, R404A, R410A, R507A, R509A, R1234yf
Applicable refrigerant (recovery)R22, R32, R134a, R404A, R407C, R410A, R1234yf etc.
Recovery methodLiquid recovery (Vapor recovery is also possible)
Reclaim methodElectrostatic separation method
Voltage220-240V
Compressor750W, oil-less
Oil separatorHeat exchange style, Capacity 2L
Weight60kg
Operating temperature5~35°C
Applicable cylinderFloat sensor: RECOVERY CYLINDER WITH FLOAT SENSOR (6L. 12L, 24L, 40L, 120L) Weighing: ROCEVERY CYLINDER WITHOUT FLOAT SENSOR(24L, 120L)
Standard accessories1/4″CHARING HOSE183cm WITH BALL VALVE(red, blue) x each 1pce AR FILTER CORE, FILTER

ECOsaver V240SP

  • High durability 1HP compressor. High speed portable recovery machine has a 1HP twin compressor.
  • Stable cooling capacity. Large air flow geared fan with clutch function cools down the condenser and compressor stably.
  • Stable start and running. Two capacitors for starting and running ensures stable operation even at low voltage.
  • Easy operation. Anyone can operate easily with single valve
  • Self-cleaning function. Residual liquid refrigerant in the machine can be recovered to the cylinder to prevent the refrigerants from mixing.
ItemECOsaver V240SP
Code No.ES641
Applicable refrigerant (recovery & reclaim)R12, R22, R32, R500, R502, R134a, R404A, R410A, R507A, R509A, R1234yf
Applicable refrigerant (recovery)R22, R32, R134a, R404A, R407C, R410A, R1234yf etc.
Recovery methodCompressed vapor recovery method/Push-pull method
Reclaim methodElectrostatic separation method
Voltage220~240V(50/60Hz)
Compressor750W Oil-less twin cylinder
Weight16.3kg
Operating temperature0~40°C
Ultimate vacuumMax. -0.09MPa
Applicable cylinderFloat sensor: RECOVERY CYLINDER WITH FLOAT SENSOR (24L, 40L, 120L) Weighing: RECOVERY CYLINDER WITHOUT FLOAT SENSOR (24L, 120L)
Standard accessories1/4″CHARGING HOSE 152cm, 1/4″ CHARING HOSE WITH BALL VALVE 152cm, HOSE ADAPTER FOR R410A 5/16″ FEMALE×1/4″MALE, FILTER, SHOULDER BELT, POWER CORD

ECOsaver Tetra

  • Quadruple compressor. New designed horizontally opposed quadruple compressor increases liquid / vapor recovery speed significantly. Horizontally opposed pistons are free from poor compression by wear and it maintains maximum performance.
  • Compact & light weight. Can be carried by one person as it weights only 22kg and compact.
  • High durability & long life. High speed turbine fan cools down compressor head and condenser, and realizes high efficiency and durability. Refrigerant never enter to the crank case and it prevents damage on bearings etc. Possible to recovery refrigerant which contains no oil too.
  • Outstanding recovery rate. Easy to recover even from large systems.
  • Self-cleaning function. Residual liquid refrigerant in the Machine can be recovered to the cylinder to prevent the refrigerants from mixing.
ItemECOsaver Tetra
Code No.ES802
Applicable refrigerant (recovery & reclaim)R12, R22, R500, R502, R115, R125, R218, R134a, R401A, R401B, R402A, R402B, R404A, R407A, R407B, R407C, R407D, R407E, R407H, R32, R410A, R410B, R422A, R422D, R448A, R449A, R452A, R463A※, R463AJ, R507A, R509A, R1234yf, R1234ze
Recovery methodCompressed vapor recovery method/Push-pull method
Voltage220~240V(50/60Hz)
Compressor750W Oil-less twin cylinder
Weight16.3kg
Operating temperature0~40°C
Ultimate vacuumMax. -0.09MPa(-675mmHg)
Applicable cylinderFloat sensor: RECOVERY CYLINDER WITH FLOAT SENSOR (24L, 40L, 120L) Weighing: RECOVERY CYLINDER WITHOUT FLOAT SENSOR (24L, 120L)
Standard accessories3/8″ CHARING HOSE 153cm 2pcs、3/8″ BALL VALVE FEMALE×MALE HOSE ADAPTER FOR R410A 5/16″FEMALE×3/8″MALE, HOSE ADAPTER 1/4″FEMALE×3/8″MALE, FILTER

Bacharach offers innovative solutions for precision instrumentation that makes HVAC-R safer, cleaner, and more energy-efficient. Through over 100 years of innovation, Bacharach is proud to provide customers with clean-tech solutions for gas and refrigerant leak detection, combustion and emissions analysis instrumentation, and energy management for commercial and industrial applications. in HVAC industry Bacharach is famous for their portable gas detection and monitoring instrumentation.

Single- and Multi-zone Aspirated Leak Detectors

  • 1 ppm Minimum Detectable Level. Detects leaks that other instruments can’t
  • Early detection of refrigerant leaks. Mitigate refrigerant loss, protect produce, enhance energy efficiency
  • Monitors up to 16 remote areas, expandable to 48 monitoring points. Ideal solution for grocery store refrigerant monitoring
  • Over 50 different refrigerants accurately detected. Monitor multiple refrigerant circuits with a single detection system
  • Infrared sensor technology. Accurate, precise measurement unaffected by other gases, temperature or humidity
  • High performance sampling pump. Industry-leading cycle times for monitoring all zones with greater frequency
  • Minimal maintenance and no calibration required. Low cost of ownership
  • Halogen, CO2 and NH3 versions available. Suitable for a variety of refrigerant monitoring applications
MeasurementUnitDescription
GAS LIBRARY
HGM-MZ
FA188, FC72, H1211, H1234ZE, H1301, H2402, HFP, N1230, N4710, N7100, N7200, N7300, N7600, R-11, R-113, R-114, R-12, R-124,
R-125, R-21, R-227, R-23, R-236fa, R-245fa, R-401A, R-402A, R-402B, R-404A, R-407A, R-407F, R-408A, R-409A, R-422A,
R-422D, R-424A, R-426A, R-427A, R-438A, R-448A, R-449A, R-452A, R-452B, R-500, R-502, R-503, R-507, R-508B, R-513A,
R-514A, R-1233zd, H1233ZDE, N4710, R448A, R449A, R513A, R452A, R452B, R514A, H1336E, H1336Z, N5110, R454A, R454C,
R455A, HFO1224YDz, FC-3284
CO2-MZCarbon Dioxide (CO2), R744
MEASURING RANGEHGM-MZAll gases 0 to 10,000 ppm
CO2-MZCarbon Dioxide 0 to 8,000 ppm
AccuracyHGM-MZ1 ppm Minimum Detectable Level (MDL) (most gases)
±1 ppm ±10% of reading from 0-1,000 ppm (most gases)
±1 ppm ±2% of reading with field calibration (most gases)
±10 ppm ±15% of reading from 0-1,000 ppm (R-11, R-21, R-32, R-113)
CO2-MZ±5 ppm ±5% of reading from 0-1,000 ppm, ±10% of reading from 1,000-4,000 ppm, ±15% of reading from 4,000-8,000 ppm
TEMPERATURE DRIFTHGM-MZ±0.8% (R-134a) of reading per degree C between purge cycles
CO2-MZLess than 1 ppm per degree C between purge cycles

MGS-550 Dual Gas Detector

  • IP66-rated enclosure protects from dust and water ingress
  • Two-sensor capability allows for unparalleled flexibility and enables detection of multiple target gases in a variety of ranges or locations (local and remote sensors available)
  • 5-digit LED display shows real-time concentration readings and makes configuration and self-diagnostics intuitive
  • Configurable analog output (4-20mA, 0-5V, 0-10V, 1-5V or 2-10V) and Modbus communications for integration with Bacharach’s MGS-408 controller or third-party BMS / BAS control systems
  • Three user-configurable relays (fault, low and high alarm) may be used to activate external beacons / sounders, ventilation or other countermeasures
  • Integrated audible / visual alarms for refrigeration safety compliance – no additional hardware
A2LYes
AlarmIntegrated Audible / Visual Alarm
Ambient Temperature-40 to 122°F (-40 to +50°C)
Approvals / StandardsEMC Directives, CE Mark, UL / CSA / IEC 61010-1
Digital CommunicationsCarbon Monoxide (CO), Hydrocarbons, LPG, Nitrogen Dioxide (NO2), R-1234yf, R-1234ze, R-134a, R-22, R-290 (Propane), R-32, R-404A, R-407A, R-407C, R-407F, R-410A, R-422A, R-422D, R-427A, R-448A, R-449A, R-452A, R-50 (Methane), R-507A, R-513A, R-600 (Butane), R-717 (Ammonia), Oxygen (O2), R-744 (CO2)
Product Dimensions (L×W×H)8.3” × 8.9” × 3.4” (210 mm × 225 mwm × 85 mm)
User Interface5-digit, 7-segment red/green LED; configuration push buttons and magnetic switches
Wiring2 A @ 30 VDC, 0.5 A @ 125 VDC, 0.25 A @ 250 VAC
AccuracySC – < -10%/+15% of Full-Scale; IR, Cat, EC – < ±5% of Full-Scale
Altitude0 to 6,560 ft (2,000 m)
Analog Communication4 to 20 mA, 0 to 5V, 0 to 10V, 1 to 5V, 2 to 10V
Enclosure RatingIP66
Humidity5 to 90 %RH, non condensing
Operating Voltage24 VDC or 24 VAC
Supports/Enables Compliance with Industry Codes & RegulationsASHRAE 15, CSA B52.2, EN 378*, F-Gas Regulation
Warranty1 Year

VRF Refrigerant Gas Detection

  • Centralized monitoring for multi-occupant applications utilizing the MVR-300™ VRF Refrigerant Gas Detector
  • At-a-glance visualization of whole system alarm, fault, or connectivity status
  • Continuously monitors up to 100 connected devices for alarm and fault conditions, ensuring and warning in case of any disconnect
  • Rolling event log of 100 most recent events (alarms, faults, connectivity, etc.) saved to SD card
  • 1 Alarm Relay; 1 Fault Relay; automatic system action to be taken for fault or alarm condition via built-in relays
  • Self diagnostics and simple field calibration for easy maintenance
  • Commissioning via dynamic device pairing and remote Modbus auto-assign save
AlarmIntegrated Audible / Visual Alarm
Ambient Temperature32 to 122°F (0 to 50°C)
Buzzer Volume80 dB @ 10 cm
Display Size5 inch 800 × 480 pixels
HumidityHumidity: 5 to 90% RH, non-condensing
Operating Temperature32 to 122°F (0 to 50°C)
Output2 x Relays Modbus
Product Dimensions (L×W×H)13.56” × 11.43” × 5.46” (344 × 291 × 139 mm)
User Interface4.5″ Color Touch Display
Wiring2A @ 30 VDC/250VAC
Altitude0 to 6,560 ft (2,000 m)
Approvals / StandardsCE, UL/CSA/IEC/EN 61010-1
Digital CommunicationsModbus RTU via RS 485
Max Number of Sensor Inputs100
Operating Voltage24 VDC or 24 VAC
Product Weight7.8 lb (3.54 kg)
Warranty1 Year

Tasco Japan is a prominent name in HVAC tools especially in the category of mechanical tools such as vacuum pump, leak detector and manifold. Since it was established in February 1975, TASCO has expanded its business focusing on air conditioning tools development, manufacturing and import. Effective from April 1, 2015, Tasco Japan Co. Ltd. changes its name to ICHINEN TASCO CO., LTD.

Vacuum Pump (TA150SV-EXP)

  • Smallest in class: 215 × 120 × 160 mm. Lightest in class: 2.95kg
  • Anti Oil Backflow. Prevents cross contamination of vacuum pump oil and compressor oil by the failure of power supply.
  • Large Sight Glass for monitoring vacuum pump oil
  • Gas Ballast Valve helps the attainment of deep ultimate vacuum. It also prevents the deterioration of vacuum pump oil.
Part No.TA150SV-EXP
Free Air Displacement1.4CFM (40L/min.)
RotorSingle Stage
Ultimate Vacuum95 microns
Voltage220~240V
Motor / RPM60W 2880 r.p.m.
Vacuum Pump Oil Capacity 90 ml
Intake Fitting5/16″ (1/2-20UNF)
Dimensions / Weight120W × 215D × 160H mm / 2.95kg
Accessories1/4″ Male × 5/16″ Female adapter (TA159P-4)
OptionsVacuum gauge kit (TA142MK-EXP, TA142MD),
Carrying case (TA150PS, TA150CS-21)

Leak Detector

  • Infrared Detection (NDIR). Dispersive infrared technology quickly and accurately detects the refrigerant leak, and does not react to nuisances such as oil and moisture.
  • Long Sensor Life. Provides a long-term stable performance.
  • LED Bar Display. The 9 LED bar display from green to red indicates the degree of refrigerant concentration in air.
  • Turbo Mode. Quick and easy for identifying the smallest leaks.
  • Long Battery Life. 5 hours continuous use after a charge.
Part No.TA430D
RefrigerantsR410A, R32, R407C, R404A, R134a, R1234yf, R22, R12, etc.
Sensitivity[TURBO]3g/year, [HI] 10g/year, [MID]50g/year, [LO] 100g/year
Leak IndicationAudible and Visual LED bar indicator
Warm-up Time45 seconds
Auto-Off10 minutes after no activity
Operating Environment0.40°C, 0-80%RH (non-condensing)
Probe460mm long, 14mm diameter
Battery TypeRechargeable Li-ion Battery
Dimensions and Weight198(L)X70(W) ×42.5(H)mm / 365g
AccessoriesUSB Charger (100-240V 50/60Hz), USB Cable, Carrying Casel

Manifolds

  • Class 1.6 accuracy gauges with shock resistance, vibration resistance, pulsation resistance
  • Calibration Access Port Capable to adjust to 0 even with the gauge lens on
  • Assembled in-house under thorough process control
  • Final check before shipping – Japanese commitment

Choose and buy a wide variety of tools as a set.

Scroll to Top